SECTION B: GENERAL ELECTRICAL INFORMATION
For 120V installations use two conductor, non-metallic sheath cable with
ground wire (3 wires total) for the incoming power supply on replace in-
serts. Use the appropriate wire to meet local and national electrical codes
for rated power consumption.
For 208V / 240V installations use three conductor, non-metallic sheath
cable with ground wire (4 wires total) for the incoming power supply on
replace inserts. Use the appropriate wire to meet local and national elec-
trical codes for rated power consumption.
Two conductor, non-metallic sheath cable with ground wire (3 wires total) is
recommended for installation of a wall mounted thermostat and/or wall switch
for use on replace inserts. Use appropriate wire to meet local and national
electrical codes for rated power consumption. All wire gauges should match
the recommended wire sizes shown below.
Voltage Wire Gauge Fuse Rating
120 Volts 12 Gauge 15 Amp
208 Volts 12 Gauge 15 Amp
240 Volts 12 Gauge 15 Amp
!
NOTE: The trim should be in-
stalled before securing the rebox in
the opening.
There are two mounting anges
located on each side of the replace
insert.
From the inside of the unit, bend tabs
outward and mount to the inside of
the framing using suitable hardware.
Mounting
Flanges
MOUNTING FLANGES
RECOMMENDED POWER SUPPLY WIRE SPECIFICATIONS