Dimplex BFSL33 Installation Guide Page 10

  • Download
  • Add to my manuals
  • Print
  • Page
    / 19
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 9
10
www.dimplex.com
SECTION D: ALTERNATE CONTROL OPTIONS
120V MAIN POWER WALL SWITCH
FIREPLACE JUNCTION BOX
120 V
POWER
SUPPLY
(BREAKER
PANEL)
WHITE - N
RED L2
BLACK L1
WHITE – N
BLACK L1
GROUND - G
WALL
SWITCH
GROUND - G
CAUTION: The use of a wall switch to control the main power for 240V is
not recommended. To control the unit remotely the use of a Dimplex Wall
Remote - WRCPF-KIT - is suggested (sold seperately).
!
NOTE: Before installing the unit have the following wires installed:
A 2 conductor wire with ground (3 wires total) from the power supply
panel to the main switch wall box.
A 2 conductor wire with ground (3 wires total) from the main switch wall
box to the junction box on the unit.
!
NOTE: Use a single pole, single throw (On/Off) wall switch that is rated for
a minimum of 15 amps.
Locate the voltage selector switch inside the exhaust panel on the top 1.
right hand corner of the unit. Ensure that the switch is in the 120V posi-
tion. (115 is printed on switch)
Loosen the screw securing the junction box cover and remove the cover.2.
Remove the knockouts (if necessary) or use the provided cable clamp.3.
Pull out the four wires marked L1, L2, N, and G (black, red, white and 4.
green).
Connect L1 (black) from the unit to the L1 (black) from the main power 5.
wall switch using a wire connector (not supplied).
Connect the other end of L1 (black) to the L1 terminal of the main power 6.
wall switch.
Connect L2 (red) from the unit and N (white) from the unit to the Neutral 7.
wire (white) of the main power wall switch by using a wire connector (not
supplied).
Connect the other end of the N (white) to the Neutral wire (white) from the 8.
power supply panel by using a wire connector (not supplied).
Page view 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 ... 18 19

Comments to this Manuals