The BF series replaces have been tested in accordance with the UL 2021 and
CSA C22.2 No. 46 standards for xed and location-dedicated electric room
heaters.
Voltage
(Volts)
Rated
Power
(Watts)
Remote
Control
Wall
Thermostat
AMPS
No Heat
120 Volt
120
Volt
208 Volt
240
Volt
120/120/
208/240
8/1223/
1823/2423
3 Stage Optional 0.07A 10.2A 8.7A 10.1A
!
NOTE: Power ratings shown include LED lights and motors (10 watts)
WARNING: The installation of the replace unit must comply with the appli-
cable Local and/or National Electrical Codes and utility requirements. This
installation should be entrusted to duly qualied personnel where required
by law.
MODEL SPECIFICATIONS
!
NOTE: Please read all instructions before installing.
Rough in framing opening following the recommended dimensions located 1.
in Section A: Framing Dimensions.
Allow 8” (20.3 cm) of service cable for connecting power supply wire to 2.
junction box on replace when installing before nishing wall. Allow up to
4’ (121.9 cm) of service cable for connecting power supply wire to junction
box on replace when installing after nishing wall. Remove the outer
jacket and strip the individual conductors ½” (1.3 cm) from the end.
Loosen the screw securing the junction box cover and remove the cover.3.
Remove knockouts, if necessary, or use the provided cable clamp.4.
Place unit in position in the framed opening, level with shims if necessary 5.
and attach unit to frame using mounting anges provided (Figure 3).
Unit is factory wired for 208/240V power supply. If 120V operation is 6.
required, slide the switch and recongure the wiring (Section C). Wires L1,
L2, N & G are attached to the rear of the junction box cable clamp for easy
access.
!
NOTE: If wiring unit to operate with NO heat a dedicated circuit may not
be required.
Wire a dedicated, properly fused circuit with a 15amp rating for the appro-7.
priate voltage (120V, 208/240V). See Section C for factory setting wiring.
Make wall switch and or wall mounted thermostat connections as outlined 8.
in Section D.
Place all connectors inside the unit and secure the junction box cover to 9.
unit. Ensure that the cable clamp grips only the jacket of service cable,
thermostat and if applicable wall switch lines.