Page view 9
10 www.renewables.dimplex.com
Operation
CAUTION: During the initial operation some
odour may be noticed due to the newness of mate-
rials used in manufacturing. This is normal and will
disappear after a short period of use. It is however
advisable to keep the room well ventilated. Rooms
must be well ventilated and young children, caged
birds, or persons with respiratory complaints must
not remain in close proximity to the heater dur-
ing the rst 48 hours of the commissioning period.
This must be done for each heater (staggered over
a few days).
Controls
The user controls are located on the top right of
the heater. The heater is tted with an adjustable
electronic temperature controller and three but-
tons.
1. Display Screen
2. “Menu” Button
3. “Back” Button
4. “Advance” Button
5. “Selector Dial”
6. Service Menu
The minimum room temperature setting is 7°C
(45°F) and may be used for protection against
frost. The maximum temperature setting available
is 30°C (86°F).
A temperature of approximately 20°C (68°F) repre-°F) repre-repre-
sents a normal room temperature.
It is normal for the fan to stop running for periods
of time. This happens because the room tem-
perature is at or above the temperature set on the
control and the room does not need any more heat
at that time.
Control Functions
The heater controls can easily be adjusted by
using a combination of the three buttons and the
selector dial, which can be rotated and pressed.
1. DISPLAY SCREEN shows the options avail-
able at each stage of the adjustment. COM-
FORT ON/OFF illustrates the part of the time
function that is currently running.
Comfort On – will control the room to the
set temperature.
Comfort Off - will control the room to the
setback temperature.
2. MENU displays the options available;
Date/Time - Setting current date/time.
Timer Mode - Setting the timer to your indi-
vidual requirements.
Options - Temperature formats, ‘Daylight
Saving’ settings, and Setback settings.
3. BACK shows pervious programming stage.
4. ADVANCE button on the User Interface is
used to skip from the current Comfort mode
to the next – turning the heater from OFF to
ON or vise versa.
ADVANCE can also be found under the
Service Menu (See the “Service Menu”
section of this document for more details).
This Advance provides the ability to activate
a supplemental heating (boost) element,
controlled by the electronic thermostat for a
maximum of 240 minutes (4 hours), or until
Page view 9