SOLC220 – Integrated roof kit
Page 18 of 28
RK0089-4 08/09
SOLAR
Step: 16.0
The collector(s) can now be installed.
See chapter 2 for information on the
collector connections, it is critical the
collectors are orientated correctly.
- Rest the collectors on the bottom
brackets as highlighted in the image
across.
The collectors can now only move left to
right.
There are markings on the aluminium
sheets that highlight the approximate
position of the collector.
For exact location of the collectors:
- The gap between the frames of the
collectors must be 90mm and 45mm
from the centre of the rubber seal to
the frame of the collector, as illus-
trated across.
90mm
45mm
Step 17.0
To connect the inlet/outlet connections
to the collectors:
- Drill a 30mm diameter hole in the
aluminium sheets at the location of
the flow and return pipes.
A conical drill bit or a standard drill may
be used for this.
- The hole centre is to be positioned
50mm from the frame of the collector
and in line with the collector connec-
tion, as illustrated across.
- It is important that any swarf or
burred edges be removed.
50mm
ø30mm