In keeping with our policy of continuous product development, we reserve the right to make changes without notice.
© 2012 Dimplex North America Limited
Dimplex North America Limited
1367 Industrial Road
Cambridge ON Canada N1R 7G8
1-888-346-7539
www.dimplex.com
REV PCN DATE
00 - 2-APR-12
IMPORTANT SAFETY INFORMATION: Always read this manual rst before attempting to service this replace. For your
safety, always comply with all warnings and safety instructions contained in this manual to prevent personal injury or prop-
erty damage.
Page view 0
1 2 3 4 5 6 ... 12 13

Summary of Contents

Page 1 - Service Manual

Service ManualModel Number:EWMC-CC-SSEWMC-BLK-SSUL Part Number690182010069018203007400310000R01In keeping with our policy of continuous product develo

Page 2 - TABLE OF CONTENTS

10 www.dimplex.comhowever, a re initialization procedure may need to be followed. Refer to Page 4 for the Remote Control Init

Page 3 - OPERATION

11PARTIALLY REFLECTIVE GLASS REPLACEMENT WARNING: If the replace was operating prior to servicing allow at least 10 minutes for light bulbs and hea

Page 4 - Remote Control

12 www.dimplex.comPROBLEM CAUSE SOLUTIONGeneralCircuit breaker trips or fuse blows when unit is turned onShort in unit wiring

Page 5 - MAINTENANCE

13PROBLEM CAUSE SOLUTIONHeaterHeater is not turning off Improper operation Refer to Operation SectionDefective heater On/Off switch, if ap-plicableRep

Page 6 - Replacement Parts List

2 www.dimplex.comAlways use a qualied technician or service agency to repair this replace.! NOTE: Procedures and technique

Page 7 - WIRING DIAGRAM

3Manual Controls beside Logs (Figure 2):A. On/Off SwitchThe On/Off switch supplies power to the remote control receiver. When the On/Off switch is swi

Page 8 - Figure 7

4 www.dimplex.comthe replace off and it will not come back on without being reset. It can be reset by switching the On/Off

Page 9 - REMOTE CONTROL REPLACEMENT

5MAINTENANCE WARNING: If the replace was operating prior to servicing allow at least 10 minutes for light bulbs and heating elements to cool off to

Page 10 - POWER CORD REPLACEMENT

6 www.dimplex.comEXPLODED PARTS DIAGRAM624510871312111159Replacement Parts ListLOGSET ASSEMBLY 1. ...0439040100RP

Page 11 - REPLACEMENT

7WIRING DIAGRAMLampholderwireassemblyRECEIVER,REMOTE CONTROLFlickerMotorCordWide blade (N)Narrow Blade (L)SwitchLampSwitchTHERMOSTATBlowerMotorElement

Page 12 - TROUBLESHOOTING GUIDE

8 www.dimplex.comSWITCH REPLACEMENT - Heat, On/Off and 3-Position WARNING: If the replace was operating prior to servicing

Page 13 - PROBLEM CAUSE SOLUTION

9Remove the four (4) screws from bottom heater pan 5. and the two (2) screws from the front face of the heater pan.! NOTE: Front face of bottom heate