ContactDetailsPleasenotethatsomeofthecontactdetailsonthisPDFdocumentmaynotbecurrent.Pleaseusethefollowingdetailsif
9EN -www.dimplex.deUser interface (Fig.1)A Display monitorB READINGS C Key to access menuD key to access SETTINGS menuE key to access ALARM logF Keys
10EN -List of indexes and relative readings in the USER MENU (no password)READINGS menu To access the readings menu, press the key in (Fig.4); once th
11EN -www.dimplex.deUSER menu To access the USER menu, press the key in (Fig.7). Once the key has been pressed, you must insert the password to access
12EN -Setting of proportional cooling hysterisisIndex - StringMIN valueMAX valueParameter function1°C 20°CThis parameter indicates the proportional ba
13EN -www.dimplex.deSetting Cooling curve setting 1 Index - StringMIN valueMAX valueParameter function-20°C 26°CThis parameter indicates the maximum v
14EN -heating curve set 3Index - StringMIN valueMAX valueParameter function25°C 65°CThis parameter indicates the minimum value of the heating set temp
15EN -www.dimplex.deINSTALLER menuTo access the INSTALLER menu, press the key in (Fig.9). Once the key has been pressed, you must insert the password
16EN -Setting Heating limit flow temperatureIndex - StringMIN valueMAX valueParameter function30°C 70°CThe heat pumps monitor this set temperature (in
17EN -www.dimplex.deSetting supplementary electric heaterIndex - StringMIN valueMAX valueParameter function03This parameter indicates the presence of
18EN -Power for producing domestic waterIndex - StringMIN valueMAX valueParameter function0% 100%In those units that can produce domestic water, once
Air-to-Water Heat Pump for Outdoor InstallationLAB 07MLAB 09MLAB 11MEnglishInstallation and Operating InstructionsFD 8910User ManualUser ManualControl
19EN -www.dimplex.deMax external temperature for operationIndex - StringMIN valueMAX valueParameter function070This parameter lets you establish the r
20EN -Air temperature limit 1Index - StringMIN valueMAX valueParameter function-25°C 45°CThis parameter indicates the outside air temperature correspo
21EN -www.dimplex.deAir temperature limit 2Index - StringMIN valueMAX valueParameter function-25°C 45°CThis parameter indicates the outside air temper
22EN -Managing the electric heaterThe units with moducontrol offer the possibility to manage an electric he-ater; this heater can be managed in differ
23EN -www.dimplex.deELECTRIC HEATER menuTo access the ELECTRIC HEATER menu, press the key in (Fig.14). Once the key has been pressed, you must insert
24EN -Setting supplementary electric heater setpointIndex - StringMIN valueMAX valueParameter function0°C 65°CThis parameter indicates the deviation f
25EN -www.dimplex.deTable of DIP-SWITCH configurationApart from the parameters that can be inserted from the electronic control pa-nel, the units are
26EN -Table of alarmsThe units have two types of malfunctioning warning:• pre-alarm• alarmThe first type is indicated by the flashing of the red indic
27EN -www.dimplex.de10 110 High force gas temperature This warning appears when the force gas temperature (SGP probe) exce-eds the threshold set in th
28EN -32 132 Excessive temperature of cooling blade33 133 Overcurrent in acceleration Hardware error.34 134 Overcurrent at constant speed Hardware err
www.dimplex.deDeclaration of Conformity
Glen Dimplex Deutschland GmbHGeschäftsbereich DimplexAm Goldenen Feld 18D-95326 KulmbachSubject to alterations and errors. +49 (0) 9221 709 565www.dim
ContentsWarnings regarding the documentation ... 5Fundamental safety rules ...
Enabling domestic hot water preparation ... 17 Power for producing domestic water ..
5EN -www.dimplex.de1 Warnings regarding the documentation 1.1 Use in compliance with the documentationThe Dimplex LAB units are constructed according
6EN -Description of the controllerThe control panel of the unit allows the rapid setting and display of the wor-king parameters of the heat pump. The
7EN -www.dimplex.deMODUCONTROL default settingsUSER menu - (Password 000)LABStA StF bnF StC bnC CSt SF1 tF1 SF2 tF2 SC1 tC1 SC2 tC2 SAS bAS0123456789A
8EN -ELECTRIC HEATER menu - (Password 001)LABSrA brA Sri bri tA1 tA2 bA012345641312-302Index - String Meaning of parameter0 - Sra Freeze protection a