Dimplex BF39STP/DXP User Manual Page 3

  • Download
  • Add to my manuals
  • Print
  • Page
    / 21
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 2
Listing and Code Approvals
The BF series fireplaces have been tested in accordance with the UL 2021 and CSA C22.2 No. 46 standards for
fixed and location-dedicated electric room heaters.
Model Specifications
Model
Number
Description
Voltage
Volts
Rated Power Watts
Remote
Control
Wall
Thermostat
Refractory
Brick Look
AMPS
No Heat
120 Volt
AMPS
120
Volt
AMPS
208
Volt
AMPS
240
Volt
BF45DXP 45” Deluxe
120/120/
208 /240
245/1440/2100/
2700
Option Option Included 2.0 12.0 10.10 11.25
BF39DXP
39” Deluxe
120/120/
208/240
245/1440/2100/
2700
Option Option Included 2.0 12.0 10.10 11.25
BF39STP 39” Std.
120/120/
208/240
245/1440/2100/
2700
Option Option N/A 2.0 12.0 10.10 11.25
BF33DXP 33” Deluxe
120/120/
208/240
245/1440/2100/
2700
Option Option Included 2.0 12.0 10.10 11.25
BF33STP 33” Std.
120/120/
208/240
245/1440/2100/
2700
Option Option N/A 2.0 12.0 10.10 11.25
Note: Power ratings shown include the light bulbs and motors (275 watts)
The installation of the fireplace unit must comply with the applicable Local and/or National
Electrical Codes and utility requirements. This installation should be entrusted to duly qualified
personnel where required by law.
Step-by-Step Installation
(Note: Please read all instructions before installing)
1. Rough in framing opening following the recommended dimensions located in
(Section A: Framing).
2. Allow 8” of service cable for connecting power supply wire to junction box on fireplace
when installing before finishing wall. Allow up to 4 feet of service cable for connecting
power supply wire to junction box on fireplace when installing after finishing wall.
Remove the outer jacket and strip the individual conductors ½” from the end.
3. Loosen the screw securing the junction box cover and remove the cover.
4. Remove knockouts if necessary or use the provided cable clamp.
5. Place unit in position in the framed opening, level with shims if necessary and attach
unit to frame using mounting flanges provided (see figure 3 on page 3).
6. Unit is factory wired for 208/240 volt power supply (see figure 1 on page 3). If 120 volt
operation is required, slide the switch and reconfigure the wiring
(see figure 2 on page 3). Wires L1, L2, N & G are attached to the rear of the junction
box cable clamp for easy access.
Note
If wiring unit to operate with NO heat a dedicated circuit may not be required.
7. Wire a dedicated, properly fused circuit with a 15amp rating for the appropriate voltage
(120, 208/240). (see Section C for factory setting wiring)
8. Make wall switch and or wall mounted thermostat connections as outlined in Section D:
Wiring.
9. Place all connectors inside the unit and secure the junction box cover to unit. Ensure
that the cable clamp grips only the jacket of service cable, thermostat and if applicable
wall switch lines.
1
Page view 2
1 2 3 4 5 6 7 8 ... 20 21

Comments to this Manuals

No comments