INSTALLATION GUIDE FOR THE ELECTRIC FIREPLACE MODEL NUMBERS: BF45DXP BF39STP/DXP BF33STP/DXP 7206350500rev02
240 Volt Main Wall Switch Wiring Diagram 8 FIREPLACE JUNCTION BOX 240 V POWER SUPPLY (BREAKER PAN
Main Power Wall Switch Wiring For 120 Volt NOTE: This option should not be used with the remote control kit. NOTE: Before installing the unit have t
120 Volt Main Wall Switch Wiring Diagram 10 FIREPLACE JUNCTION BOX 120 V POWER SUPPLY (BREAKER PA
Main Power Wall Switch Wiring For 120 Volt No Heat Installation NOTE: This option should not be used with the remote control kit. NOTE: Before insta
WIRE NUTS 120 Volt Main Wall Switch Wiring Diagram No Heat Installation FIREPLACE JUNCTION BOX 120 V
Section E: Heater Wall Switch and Wall Thermostat Wiring Options Heater Wall Switch Wiring For 120/240 Volt NOTE: Before installing the unit co
Heater Wall Switch Wiring Diagram For 120/240 Volt (See Section C or Section D For Main Power Connection)
Wall Mounting Thermostat Wiring For 120/240 Volt NOTE: Before installing the unit complete the following: 1. Install main power connection with ap
Wall Mounted Thermostat Wiring Diagram For 120/240 Volt (See Section C or Section D For Main Power Connection)
Flame override Switch Wiring For 120/240 Volt NOT AVAILABLE WITH NO HEAT INSTALLATION NOTE: The fireplace can be wired to have a wall switch operat
CONTENTS PAGE 1 Listings and Code Approvals PAGE 1 Model Specifications PAGE 1 Step-by-Step Installation Section A PAGE
Flame Override Wall Switch Wiring Diagram For 120/240 Volt (See Section C or Section D For Main Power Connection) NOT AVAILABLE WITH NO HEAT INSTALLA
Wiring Diagram *Note: standard models do not have a log driver 1-888-DIMPLEX 1-888-346-7539 1367
Listing and Code Approvals The BF series fireplaces have been tested in accordance with the UL 2021 and CSA C22.2 No. 46 standards for fixed and loca
WARNING Ensure method of installation does NOT obscure the air intake slots on bottom front of unit in any manner. (see diagram in Section A) Sectio
Voltage Selector Switch Location IMPORTANT: Ensure that the incoming power supply voltage matches the setting of the voltage selector switch. NOTE
Section C: Factory Setting Wiring (Without Main Power Wall Switch) IMPORTANT: The unit is factory configured for 208/240 volt operation NOTE: Use 3
Section C: Factory Setting Wiring (Without Main Power Wall Switch) IMPORTANT: The unit is factory configured for 208/240 volt operation NOTE: Use 2
WIRE NUTS Section C: Factory Setting Wiring (Without Main Power Wall Switch) (No Heat Installation) IMPORTANT: The unit is factory configured for 2
Section D: Main Power Wall Switch Wiring Options Main Power Wall Switch Wiring For 240 Volt NOTE: This option should not be used with the remote c