Dimplex WRCPF-KIT Installation Guide

Browse online or download Installation Guide for Remote controls Dimplex WRCPF-KIT. Dimplex WRCPF-KIT Installation guide User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 14
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Installation Guide
Model
BF33STP/DXP
BF39STP/DXP
BF45DXP
IMPORTANT SAFETY INFORMATION: Always read this manual rst before attempting to install or use this replace. For your
safety, always comply with all warnings and safety instructions contained in this manual to prevent personal injury or property
damage.
To view the full line of Dimplex products, please visit
www.dimplex.com
7206350500R03
Page view 0
1 2 3 4 5 6 ... 13 14

Summary of Contents

Page 1 - Installation Guide

Installation GuideModelBF33STP/DXPBF39STP/DXPBF45DXPIMPORTANT SAFETY INFORMATION: Always read this manual rst before attempting to install or use thi

Page 2 - Table of Contents

10www.dimplex.com! NOTE: This option should not be used with the remote control kit.! NOTE: Before installing the unit have the following wires instal

Page 3 - STEP-BY-STEP INSTALLATION

11! NOTE: Before installing the unit complete the following:Install main power connection with appropriate wiring - directly to the main power or thro

Page 4 - MOUNTING FLANGES

12www.dimplex.com120V/240V WALL MOUNTED THERMOSTAT! NOTE: Before installing the unit complete the following:Install main power connection with appropr

Page 5 - 240 Volts 12 Gauge 15 Amp

13120V/240V WALL MOUNTED FLAME OVERRIDE SWITCHDO NOT USE WITH NO HEAT INSTALLATIONS! NOTE: The replace can be wired to have a wall switch operate the

Page 6 - 120V INSTALLATION

14www.dimplex.comWALL REMOTE - WRCPF-KIT14Room Temperature1. Set Temperature2. Flame Effect3. Purire™4. Heat Off Indicator5. Function Lock Indicator6

Page 7

2www.dimplex.comListing and Code Approvals ...3Model Specications. . . . . . . . . . .

Page 8 - 240V MAIN POWER WALL SWITCH

3The BF series replaces have been tested in accordance with the UL 2021 and CSA C22.2 No. 46 standards for xed and location-dedicated electric room

Page 9 - 120V MAIN POWER WALL SWITCH

4www.dimplex.comJKLFRAMING DIMENSIONSRough-In Framing Dimensions Firebox Dimensions Rough-In Corner FramingThis replace is a zero clearance design. N

Page 10 - FIREPLACE JUNCTION BOX

5SECTION B: GENERAL ELECTRICAL INFORMATIONFor 120V installations use two conductor, non-metallic sheath cable with ground wire (3 wires total) for the

Page 11 - NOTE: This only illustrates

6www.dimplex.com! IMPORTANT: The unit is factory congured for 208/240V operation.! NOTE: Use 3 conductor wires with ground (4 wires total) from the p

Page 12

7Remove the knockouts (if necessary) or use the provided cable clamp.3. Pull out the four wires marked L1, L2, N, and G.4. Connect L1 (black) wire fro

Page 13 - ame switch connection

8www.dimplex.comSECTION D: ALTERNATE CONTROL OPTIONS240V MAIN POWER WALL SWITCH! NOTE: This option should not be used with the remote control kit.! NO

Page 14 - UNIT INTERNAL WIRING DIAGRAM

9120V MAIN POWER WALL SWITCH FIREPLACE JUNCTION BOX 120 V POWER SUPPLY (BREAKER PANEL) WHITE - N RED – L2 BLACK – L1 WHITE – N BLACK – L1 GROUND -

Comments to this Manuals

No comments