- 8 -
English
Electrical Connection
WARNING – THIS APPLIANCE MUST BE EARTHED
The installation of this appliance should be carried out by a competent electrician in accordance with I.E.E. Regulations for Electrical
Equipment. The radiator is tted with two exible cables for connection to the xed wiring of the premises through suitable connection
boxes positioned adjacent to the radiator. Each supply circuit to the radiator must incorporate a double pole isolating switch having a
contact separation of at least 3mm. This radiator is not suitable for connection to a 30A ring circuit.
THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE
NOTE ALSO THE INFORMATION GIVEN ON THE APPLIANCE
IMPORTANT SAFETY ADVICE
WARNING - This radiator is VERY HEAVY, it is essential that the radiator is FIXED SOUNDLY TO A WALL and mounted on
a FIRM, LEVEL SURFACE.
WARNING – Choose the appropriate xings to securely attach the radiator to the wall;
Suggested Wall Fittings (see page 5 for further information)
Solid brick/block: Size 10 plastic inserts (provided). 8mm drill bit. Drill 15mm deeper than insert length.
Plasterboard: If possible locate studding and use No. 10 woodscrews directly into the wood, otherwise
M5 intersets.
For other wall types seek specialist advice.
WARNING – If during any reassembly of the radiator, a part of the thermal insulation shows damage or deterioration which
may impair safety, it should be replaced with an identical part.
WARNING – This radiator must not be located below a xed socket outlet.
WARNING - in order to avoid overheating, do not cover the radiator.
DO NOT COVER OR OBSTRUCT the surfaces of the appliance.
DO NOT POSITION under windows where curtains may contact the radiator (see minimum clearances on Page 3).
DO NOT PLACE OBJECTS in contact with the radiator.
DuoHeat Radiators are not suitable for installation in bathrooms, shower rooms etc. or in areas of high humidity.
TO ENSURE THIS APPLIANCE IS OPERATING CORRECTLY, IT IS ESSENTIAL TO PERFORM THE CHECK PROCEDURE DETAILED
ON THE BACK PAGE OF THIS INSTRUCTION. THIS MUST BE COMPLETED BEFORE NORMAL OPERATION COMMENCES.
ATTENTION : IN ORDER TO AVOID OVER HEATING DO NOT COVER THE HEATER
Energy Retention Cells
Energy retention cells are supplied separately to the radiator in packs of two.
The reference number is 85743.
Duo300i
8 Cells (4 Packs)
Duo400i
12 Cells (6 Packs)
Duo500i
16 Cells (8 Packs)