LISTING AND CODE APPROVALS
The BF series replaces have been tested in accordance with the UL 2021 and
CSA C22.2 No. 46 standards for xed and location-dedicated electric room
heaters.
Voltage
Volts
Rated
Power
Watts
Remote
Control
Wall
Thermostat
AMPS
No Heat
120 Volt
AMPS
120
Volt
AMPS
208
Volt
AMPS
240
Volt
120/120/
208/240
8/1223/
1823/2423
Std. Option 0.07 10.2 8.7 10.1
!
NOTE: Power ratings shown include LED lights and motors (10 watts)
WARNING: The installation of the replace unit must comply with the ap-
plicable Local and/or National Electrical Codes and utility requirements.
This installation should be entrusted to duly qualied personnel where
required by law.
MODEL SPECIFICATIONS
STEP-BY-STEP INSTALLATION
(
!
NOTE: Please read all instructions before installing)
Rough in framing opening following the recommended dimensions located 1.
in (Section A: Framing).
Allow 8” of service cable for connecting power supply wire to junction box 2.
on replace when installing before nishing wall. Allow up to 4 feet of
service cable for connecting power supply wire to junction box on replace
when installing after nishing wall. Remove the outer jacket and strip the
individual conductors ½” from the end.
Loosen the screw securing the junction box cover and remove the cover.3.
Remove knockouts if necessary or use the provided cable clamp.4.
Place unit in position in the framed opening, level with shims if necessary 5.
and attach unit to frame using mounting anges provided (see gure 3 on
page 3).
Unit is factory wired for 208/240 volt power supply 6. (see gure 1
on page 6). If 120 volt operation is required, slide the switch and
recongure the wiring (Section C). Wires L1, L2, N & G are at-
tached to the rear of the junction box cable clamp for easy access.
!
NOTE: If wiring unit to operate with NO heat a dedicated circuit may
not be required.
Wire a dedicated, properly fused circuit with a 15amp rating for the appro-7.
priate voltage (120, 208/240). (see Section C for factory setting wiring)
Make wall switch and or wall mounted thermostat connections as outlined 8.
in Section D.
Place all connectors inside the unit and secure the junction box cover to 9.
unit. Ensure that the cable clamp grips only the jacket of service cable,
thermostat and if applicable wall switch lines.